Adding a Meter to a Four-Wire on the Palette

To add a meter to a four-wire on the palette:

  1. In Configure Palette, add the required four-wire to the palette.

  2. To add an input meter, drag the meter from the Configure Palette toolbar to the left-hand side of the four-wire:

The left-hand side of the four-wire turns green.

The meter scale is displayed at the top of the four-wire.

  1. To add an output meter, drag the meter from the Configure Palette toolbar to the right-hand side of the four-wire.

The right-hand side of the four-wire turns green.

The meter scale is displayed at the bottom of the four-wire.

You cannot perform output level metering on ports that are not on the same system as the LMC-64 card.

If you are performing cross-system metering in a fiber-linked Eclipse system (the port being metered and the LMC-64 card are in different matrices), Clear-Com recommends placing the LMC-64 card in the matrix where most metering is likely to occur.